Across the Middle East, the line between a working clinic and a failed one, a functional tent and an abandoned one, a livable home and one that cannot survive the summer — increasingly comes down to electricity. We supply field-ready solar power infrastructure for projects where chemistry, heat, documents and handover matter as much as watt-hours.
Heat, dust, air-freight rules, tender documents and field repair are the real risks. A weekend power station can look good in a brochure and still fail a clinic, camp or government project.
Battery chemistry, operating temperature, IP rating, UN38.3, repairable parts, document pack and shipment plan are confirmed before project release — not after the equipment is already in transit.
Engineering is in Shenzhen, regional support is in Dubai, and project distributors keep the field conversation local. Hardware does not require a cloud account to switch on.
Phase 01
Phase 02
Phase 03
Most portable power equipment available worldwide is engineered for North American weekend campers. Pretty colour displays, Nickel-Manganese-Cobalt (NMC) battery chemistry, and a declared operating ceiling of +40 °C. None of that is appropriate for an Iraqi summer, a refugee airdrop, or a paediatric incubator.
We engineer to a different brief. Lithium Iron Phosphate (LFP) chemistry that does not thermal-runaway near patients. Validated continuous discharge to +55 °C. IP65/IP66 lighting for dust storms. UN38.3 air-transport clearance for humanitarian air-freight. And a deliberately repairable construction so the housing outlives the cell pack.
Designed in Shenzhen, supported by a regional liaison in Dubai, supplied to project distributors, ministries of health, UN agencies and resilience-procurement programmes across the Gulf, the Levant, North Africa and beyond.

We will not ship NMC for portable power-station product, even when it is cheaper. The thermal-runaway profile is not appropriate for indoor humanitarian or healthcare deployment.
Operating ceilings are validated through 30-day continuous-discharge test campaigns at the declared envelope — not transcribed from the cell-supplier datasheet.
Cell modules, LED arrays and DC motors are line-replaceable items. The housing is rated for 8–10 years; the cell pack is replaced once over that lifetime.
Every shipment ships with TDS, SDS, certificate-of-conformity, batch QC report and (for ≥ 50-unit project orders) third-party test report bundle.
We will not ship a power station that requires a cloud account to function. Field operators in Yemen do not have reliable mobile data; humanitarian programmes do not accept SaaS-locked equipment.
Humanitarian-allocation pricing for accredited NGOs and ministries of health is published in writing, not negotiated case-by-case. Distribution pricing is by territory contract, not first-quote.
Start a project
A project engineer will reply within one business day with a deliverable specification and shipping plan.